Type: | Dynamic Laser |
---|---|
Sample Feeding: | Wet Dispersion |
Warranty: | 1 Year |
Measuring Principle: | Full Scale Laser Diffraction |
Particle Size Range: | 0.1μm -1500μm /0.01μm -1500μm |
Detection System: | 90/96 Channel Uniformly Crossed and Area-Compensat |
Customization: |
---|
Suppliers with verified business licenses
Model | MIS800 | |
Executive standard | ISO13322-1:2004; GB/T21649.1-2008 | |
Microscopy system | Objective lens | 4X, 10X, 40X, 60X, 100X (oil) long-range achromatic (flat field) objective lens group |
eyepiece | 1X, 10X, 16X large field of view camera eyepiece | |
Stage | Manual 3D mechanical stage, size: 185mm × 140mm, Movement range: 50mm × 75mm, coarse and micro coaxial focusing, Micro-motion value: 2μm, with locking and limiting device |
|
light source | Bottom transmission light source, 6V 20W halogen lamp, adjustable brightness. Optional top metallographic projection source (with polarizer) |
|
Total magnification | 4 times - 1600 times | |
Camera system | Highest resolution | 2048×1536 |
Pixel size | 3.2μm×3.2μm | |
Imaging element | 1/1.8 inch progress scan CMOS | |
Frame rate | 6fps@2048×1536 / 10fps@1600×1200 / 15fps@1280×1024 / 30fps@640×480 | |
Highest definition | 900 line | |
Signal to noise ratio | Less than 42dB | |
Sensitivity | 1.0V@550nm/lux/S | |
output method | USB2.0 | |
Actual observation range | 1-6000μm | |
Software function | Static acquisition | Take the sample topography as a high-resolution JPG image |
Picture processing | Use a variety of drawing tools to make the image easier to handle | |
Image stitching | Seamlessly stitching multiple images, you can get more particles in the particle test to improve the representativeness of the test. At the same time, it can also be spliced after single analysis and storage, which further improves the accuracy of the results. | |
Automatic processing tool set for particles | Automated elimination of particle adhesion, automatic elimination of noise, automatic elimination of boundary incomplete particles, automatic filling of hollow areas of particles, automatic smoothing of particle edges and other 12 automatic processing tools. | |
Scale calibration | After calibration by the national standard micrometer, each test only needs to select the scale value corresponding to the objective lens to directly obtain the actual size value of the particle. | |
Single particle data | The analysis of more than 10 parameters such as cross-sectional area, volume, and aspect ratio of a single particle can be directly performed on the image. | |
Task management mechanism | Strict task management mechanism enables users to manage all test data in a well-organized manner. | |
Report output | Output the test results as a report and freely modify the report style. | |
Overall distribution characteristic parameter | Characteristic parameters of particle distribution such as D10, D50 (median diameter), D90, D100, etc. | |
Report parameter | Cumulative distribution of overall frequency distribution | Data distribution, graph, histogram, etc. of frequency distribution and cumulative distribution of particles distributed by quantity, volume, area, etc.. |
Statistical mean diameter | Common statistical average diameters such as Xnl, Xns, Xnv, Xls, Xlv, and Xsv | |
Shape parameter | More than 10 commonly used data to characterize particle shape, such as aspect ratio, bulk ratio, sphericity, surface area, specific surface area, and circumscribed rectangular parameters | |
Statistics | Directly obtain the number of particles observed | |
Sample thumbnail | Sample color or black and white (optional) thumbnails can be displayed in the report |
|
Header input | You can enter multiple information such as sample name, test unit, and dispersion medium into the report header. |